Air cooler layout requirements

Air cooler layout of the general requirements:
1. Air cooler (hereinafter referred to as air cooler) should be arranged on the leeward side of the annual minimum frequency wind direction;
2. Air cooler should be arranged above the main gallery, the top of the framework or tower;
3. Air cooler should not be arranged at the operating temperature equal to or higher than the ignition point of the material and transportation, storage of liquefied hydrocarbon equipment above; Otherwise, non-combustion materials should be used partition isolation protection;
4. When multiple sets of air coolers are arranged together, they should be arranged in the same form and should be arranged in an in-line arrangement; part of the air-conditioners should be arranged in rows and arranged in rows;
5. Inclined roof-type air cooler should not be facing the ventilation of the dominant summer wind direction. Oblique-top air-cooler should be arranged in columns, such as arranged in rows, the middle of the two rows should have a space of not less than 3m;
6. Arranged side by side between the two humidification air coolers or dry air coolers framework of the distance between the columns should not be less than 3m;
7. Air cooler tubes at both ends of the tube and transmission machinery should be set up platform;
8. Arrange the air cooler on the side of the structure or main gallery ground should have the necessary maintenance sites and access.
       